Refrigerant Pump, Airborne Electronics Cooling

P-328, 328-D-001

Features & Benefits

The challenges of pumping a refrigerant are unique, from the subtleties of moving liquid near its saturation temperature to efficiently pumping such a low-viscosity fluid.  Cascon developed the technology and know how to design products that reliably meet these challenges for cooling applications including airborne power electronics.

  • 400 Hz AC Drive Motor
  • Flooded Motor (No rotary Seals)
  • Axial inducer 1st stage and Centrifugal Impeller 2nd Stage
  • Ultra-low inlet pressure capability

Performance Parameters

Part Number
328-D-001
Application Fluid
R1234z(e), R134a
Supply Operating Voltage
115 VAC / 400 Hz
Drive Type
Electric
Pump Type
Centrifugal
Weight
10.5 lbs
Circuits
Circuit Max Flow Max Pressure Operating Speed
Single-circuit 8.85 gpm 45 psi 11750 rpm
Inlet Pressure, Above Saturation
1.2 psia
Fluid Temp
64 DegC

Airborne Electronics Cooling